10 / Safety basics

Fire, ingress and insulation safety

Glow-wire, flame and tracking tests, plus IP and IK ratings — the material and enclosure evidence that underpins most product safety files.

Standards covered
  • IEC 60695-2-10 / -2-12 glow wire
  • IEC 60695-11-10 / -11-20 flame
  • IEC 60112 tracking index
  • IEC 60695-10-2 ball pressure
  • IEC 60529 (IP code)
  • IEC 62262 (IK code)
Sample requirements

Material plaques or finished parts; for IP and IK, the complete production enclosure

Typical turnaround

5–9 working days once the specimen form is confirmed

Scope at a glance

What this covers, and why it matters

The short version before the detail — product families, typical use, and the practical difference our scope makes.

Product families
  • Insulating materials and plastic parts
  • Printed circuit assemblies
  • Enclosures, seals and cable entries
  • Outdoor and industrial housings
  • Components needing tracking or flame evidence
Typical applications
  • Material qualification at design stage
  • IP / IK claims for outdoor products
  • Closing gaps in a safety file
  • Supplier material approval
What you gain
  • Result tied to the exact material grade and thickness
  • Datasheet claims verified on real specimens
  • Ratings that can be defended in a file review

Before a product can be judged against its own standard, the materials and the enclosure have to be characterised. Flammability, tracking resistance and ingress protection are the three areas most often left to a supplier datasheet — and the three most often challenged when a file is reviewed.

Product coverage

We test insulating materials, printed board assemblies, enclosures and seals against the general safety test family: glow-wire and needle-flame, horizontal and vertical flame, comparative tracking index, ball-pressure and indentation tests, enclosure protection against solid objects and water, and resistance to mechanical impact.

  • Glow-wire ignitability and glow-wire flame propagation to IEC 60695-2-10 / -2-12.
  • Vertical and horizontal flame to IEC 60695-11-10 / -11-20, aligned with UL 94 classifications.
  • Comparative tracking index to IEC 60112, and ball pressure to IEC 60695-10-2.
  • Ingress protection to IEC 60529 (IP) and impact protection to IEC 62262 (IK).

Why the sample form matters

A flammability result belongs to a specific thickness, colour and material grade. Changing any of those can change the classification. We record the exact test specimen in the report so the result can be matched to the material actually used in production, rather than to a similar-looking sample from a supplier.

Where it applies

Material qualification at the design stage, component approval for a larger assembly, and gap-closing when a safety report is missing enclosure or tracking evidence. IP testing is routinely requested for outdoor, wash-down and dusty-environment products.

What the report tells you

A classification or rating with the test conditions attached, photographs of the specimens, and a short note on which material variables would invalidate the result. When a product needs a full safety report, these tests slot into that plan rather than standing alone.

What you receive

  • Classification or IP / IK rating report
  • Specimen description with thickness and grade
  • Photo record of test conditions
  • Note on result validity limits

Frequently asked

Can a supplier datasheet replace this testing?

It can support a design decision, but a compliance file normally needs evidence on the material as used. We can check a datasheet and tell you what is missing.

Does an IP rating need the whole product?

Yes. The rating applies to the complete enclosure with its seals and cable entries, not to an empty housing.

Do you test UL 94 classifications?

We use the IEC 60695 methods aligned with those classifications. State the target classification when you enquire.