Industrial, scientific and medical EMC
CISPR 11 / EN 55011 and FCC Part 18 for ISM equipment — emissions and immunity for equipment that sits outside the consumer EMC regime.
- CISPR 11 / EN 55011 Class A and B
- FCC Part 18
- GB 4824
- IEC / EN 61000-4-2, -4, -5, -8, -11
- IEC / EN 61000-3-2 / -3-3
One representative unit in its production enclosure, with the cabling and load used in normal operation
7–12 working days; larger systems are quoted per project
What this covers, and why it matters
The short version before the detail — product families, typical use, and the practical difference our scope makes.
- Industrial process and control equipment
- Laboratory and analytical instruments
- Induction and dielectric heating equipment
- Medical electrical equipment
- Welding power sources
- CE and FCC files for ISM equipment
- Class determination for a new instrument
- On-site assessment of large installations
- Immunity checks for plant environments
- Class chosen from the real use environment
- Emissions and immunity in one plan
- US and EU limits reported side by side
Industrial, scientific and medical equipment is assessed under a different emissions standard from consumer products, and the class you claim changes the limits. Class A and Class B are not interchangeable: a laboratory analyser sold into a home environment has to meet the stricter set.
Product coverage
The scope covers industrial process equipment, induction and dielectric heating equipment, laboratory and analytical instruments, and medical equipment where the ISM emission standard applies. We assess conducted and radiated disturbance and, where the product environment requires it, immunity to the IEC 61000-4 series.
- Conducted and radiated emissions to CISPR 11 / EN 55011, Class A or Class B.
- FCC Part 18 measurements for the United States market.
- GB 4824 for the domestic market.
- Immunity to IEC 61000-4-2, -4, -5, -8 and -11 where the route requires it.
Class selection is a design decision
We ask where the equipment will be used before assigning a class. An instrument demonstrated as Class A cannot simply be sold into a residential environment, and a Class B claim on a large industrial machine can be expensive to achieve. Getting the decision early is cheaper than changing the filter later.
Where it applies
Laboratory and test instruments, welding power sources, induction heaters, medical electrical systems, and production equipment installed in commercial buildings. Large fixed systems can be assessed on site where a chamber is not practical.
What the report tells you
A class statement with the rationale, emission plots with limit lines, immunity results by phenomenon, and a clear list of anything that exceeded a limit with the frequency and likely coupling path.
What you receive
- Emissions report with limit lines
- Class determination note
- Immunity results by phenomenon
- Non-compliance list with frequencies
Frequently asked
Class A or Class B — which do I need?
It depends on the intended environment. We confirm this from the product's use case before the test plan is issued.
Can you test a machine too large for the chamber?
On-site work is possible with limitations. Send the dimensions and we will tell you what can be measured.
Is FCC Part 18 the same as Part 15?
No. ISM equipment falls under Part 18. We confirm which rule applies to your product at enquiry.
You may also need
Not sure whether cross-border compliance and market access apply to your product?
Talk it through for ten minutes — product, target market and the current sticking point — and we will tell you whether to do it, and what to do first.
or call 0755-8664 2861