Lighting products and luminaires
LED modules, control gear and luminaires — safety and EMC to IEC 61347, IEC 60598, CISPR 15 and the GB equivalents.
- IEC / EN 60598-1 and 60598-2 series
- IEC / EN 61347-1 and 61347-2 series
- IEC 62031 / IEC 62560
- GB/T 19510 series
- CISPR 15 / EN 55015
- IEC / EN 61547
Two complete luminaires in the final enclosure, plus one control gear sample; include the intended driver and cabling
10–14 working days for safety plus EMC; pre-scan available earlier
What this covers, and why it matters
The short version before the detail — product families, typical use, and the practical difference our scope makes.
- LED luminaires and modules
- Self-ballasted LED lamps
- Electronic control gear and ballasts
- Fixed, portable and emergency luminaires
- Street, stage and landscape lighting
- CE / CB submissions for lighting products
- GB compliance for the domestic market
- Outdoor and wet-location product files
- Driver selection and thermal design checks
- Luminaire and control gear assessed under their own clauses
- Safety and EMC planned as one project
- Part 2 clause confirmed before the test plan is issued
Lighting is a product family with two obligations at once: the luminaire and its control gear are each assessed, and the whole assembly still has to be quiet on the mains. Treating an LED driver as a generic power supply is the usual reason a lighting file comes back with gaps.
Product coverage
We test fixed, portable, recessed, flood, street, stage and emergency luminaires; LED modules and self-ballasted lamps; electronic control gear and ballasts; and the low-voltage and landscape lighting systems that often sit outside the usual product categories.
- Luminaires to IEC / EN 60598-1 and the applicable part 2 clauses.
- Control gear to IEC / EN 61347-1 and the -2 series, including the GB/T 19510 equivalents.
- LED modules and lamps to IEC 62031 and IEC 62560.
- Conducted and radiated disturbance to CISPR 15 / EN 55015, with immunity to IEC 61547.
What the tests actually look at
On the safety side the work concentrates on earthing, protection against accidental contact, insulation resistance and dielectric strength, fault conditions, creepage and clearance, and the temperature rise of accessible surfaces. Control gear adds abnormal-operation cases that are specific to the lamp type. On the EMC side we measure terminal disturbance voltage and radiated field, then check immunity to fast transients, surges and voltage dips.
Where it applies
Commercial and public lighting, architectural and stage installations, emergency and exit lighting, horticultural and aquarium lighting, and the seasonal products that have their own part 2 clauses. Outdoor products are routinely assessed for ingress protection alongside the safety file.
What the report tells you
A scope-matched test plan, a report with clause references and measured values, and a clear statement of which edition of each standard was applied. Where a product falls between two part 2 clauses, we say so before samples move rather than after the run.
What you receive
- Safety test report with clause table
- EMC test report with disturbance plots
- Temperature and dielectric measurement summary
- Edition and scope confirmation
Frequently asked
Do you test the driver and the luminaire together?
Both. The control gear is assessed under 61347 and the complete luminaire under 60598; shipping only one of the two leaves the file incomplete.
Can you cover GB and IEC editions in one run?
Where the methods overlap we run them together and report per market. Diverging clauses are listed separately.
Do outdoor luminaires need IP testing as well?
Usually yes. Ingress protection is added to the plan when the product is declared for outdoor or damp locations.